Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1293463.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 07/12/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/12/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 06/20/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/20/2018 | $0.00 | 07/12/2018 | Serious | |
| Penalty | Z: Issued | 06/12/2018 | $0.00 | 07/12/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about January 19, 2018, employees working near the vacuum pump next to the wash basin in the lab were exposed to in-running nip points and the employer did not ensure that the pump's belt was fully enclosed by a guard.