Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1288353.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 05/02/2018 2
Initial Penalty: $5,543.00
Current Penalty: $3,326.00
Issuance Date: 02/13/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0317500
Contest Date:
Final Order: 03/06/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/06/2018 | $3,326.00 | 05/02/2018 | Serious | |
| Penalty | Z: Issued | 02/13/2018 | $5,543.00 | 04/02/2018 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Facility- 30 Curry Avenue, Canonsburg, PA: On or about January 17, 2018, the employer did not develop energy control procedures for all equipment such as but not limited to the Cincinnati Dual Head Drill Press.