Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1287449.015
Citation: 01002
Citation Type: Serious
Abatement Date: 04/04/2018 2
Initial Penalty: $9,054.00
Current Penalty: $5,500.00
Issuance Date: 03/09/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 03/30/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/30/2018 | $5,500.00 | 04/04/2018 | Serious | |
| Penalty | Z: Issued | 03/09/2018 | $9,054.00 | 04/04/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown was not utilized to avoid any additional or increased hazards to employees as a result of the equipment stoppage. (a) Orma Molding Press Station #2: On or about January 09, 2018, the molding press was not denergized using the procedures established for the molding press prior to an employee conducting repairs on a pneumatic cylinder. This exposed the employee(s) to struck-by and crushing hazards, and amputation injury.