Violation Detail
Standard Cited: 19100217 C05 I Mechanical power presses.
Inspection Nr: 1287216.015
Citation: 01002C
Citation Type: Serious
Abatement Date: 08/07/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/20/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 07/17/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/17/2018 | $0.00 | 08/07/2018 | Serious | |
| Penalty | Z: Issued | 06/20/2018 | $0.00 | 08/07/2018 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.217(c)(5)(i): The employer shall use a control system and a brake monitor which comply with paragraphs (b)(13) and (14) of this section; On January 3, 2018 employees were exposed to a struck-by hazard, in that the employer did not use a control system and brake monitor on two Bliss 60 T presses.
Translate