Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1284863.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 05/29/2018 2
Initial Penalty: $7,068.00
Current Penalty: $0.00
Issuance Date: 05/16/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 06/12/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/12/2018 | $0.00 | 05/29/2018 | Serious | |
| Penalty | Z: Issued | 05/16/2018 | $7,068.00 | 05/29/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure. On or about December 19, 2017 at 265 John Brooks Road, Pendergrass, Georgia, where there was a jam that needed to be cleared in the Sidel Blow Mold machine, affected employees were used that had not been instructed ion the employer's energy control procedures. Affected employee were exposed to an amputation hazard when trying to clear a jam in the Sidel Blow Mold machine.
Translate