Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1284057.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 02/20/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/09/2018
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 03/06/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/06/2018 | $0.00 | 02/20/2018 | Serious | |
| Penalty | Z: Issued | 02/09/2018 | $0.00 | 02/20/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Lorain Tool Enterprises, Inc. - Lorain, Ohio: On or about December 18, 2017, the employer did not ensure that horizontal shafting of the model HC Hardinge Bros. lathe, located at the end of the lathe where collet handle is, was guarded to protect employees from being injured by the rotating part.