Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1283662.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 03/14/2018 2
Initial Penalty: $11,641.00
Current Penalty: $6,000.00
Issuance Date: 02/07/2018
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC): R
Gravity: 10
Report ID: 0830500
Contest Date:
Final Order: 03/02/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/02/2018 | $6,000.00 | 03/14/2018 | Serious | |
| Penalty | Z: Issued | 02/07/2018 | $11,641.00 | 03/14/2018 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Academy Roofing, Inc. at 1610 Jasper St. Aurora, CO 80011: On or before 12/8/2017 the employer did not protect employees from injury, in that the RAS Turbobend pneumatic press brake (Model 61.31, SN: 35107) which has two energy sources, did not have a specific procedure for lockout/tagout. This condition exposed employees to crushing and amputation hazards.