Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 1281353.015
Citation: 01001
Citation Type: Serious
Abatement Date: 04/26/2018
Initial Penalty: $7,853.00
Current Penalty: $0.00
Issuance Date: 04/04/2018
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): R
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 04/17/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/17/2018 | $0.00 | 04/26/2018 | Serious | |
| Penalty | Z: Issued | 04/04/2018 | $7,853.00 | 04/26/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: On or about November 30, 2017, an employee was exposed to amputation hazards from the blades of the Howden cast aluminum fan on cryovac #5 and the employer did not ensure the fan was guarded appropriately.
Translate