Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1279986.015
Citation: 01003
Citation Type: Serious
Abatement Date: 07/05/2018 2
Initial Penalty: $5,174.00
Current Penalty: $2,587.00
Issuance Date: 04/18/2018
Nr Instances: 4
Nr Exposed: 4
Related Event Code (REC): A;R
Gravity: 10
Report ID: 0112600
Contest Date:
Final Order: 05/10/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/10/2018 | $2,587.00 | 07/05/2018 | Serious | |
| Penalty | Z: Issued | 04/18/2018 | $5,174.00 | 06/05/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): At the facility at 42 Wilcox Street, Springfield, MA 01085, on 4/2/2018 and at times earlier the point of operation was not guarded for the following mechanical press brakes: (a) Columbia 10 foot press brake, model number 120 PB 10, serial number W159-11; (b) Niagara press brake, model number 1-B 36 5 6; (c) Connecticut Press Brake, press brake model number 25B614, serial number B6 444; (d) Columbia 10 foot press brake, model number 120 PB 10, serial number W159-17;
Translate