Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1277959.015
Citation: 01017
Citation Type: Serious
Abatement Date: 06/20/2018 2
Initial Penalty: $8,315.00
Current Penalty: $4,900.00
Issuance Date: 05/03/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 05/22/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/22/2018 | $4,900.00 | 06/20/2018 | Serious | |
Penalty | Z: Issued | 05/03/2018 | $8,315.00 | 06/20/2018 | Serious |
Text For Citation: 01 Item/Group: 017 Hazard:
29 CFR 1910.212(a)(5): Fan guards had openings exceeding one-half (1/2) inch: On or about 11/16/2017, at the Double R Brand Foods facility located in Lufkin Texas, the employer did not ensure that the fan blades of the motor for evaporative condensers EC2 &EC4 were guarded with guards having openings no larger than one-half inch.