Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1277932.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $12,549.00
Current Penalty: $8,784.00
Issuance Date: 12/18/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0111100
Contest Date:
Final Order: 01/11/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/11/2018 | $8,784.00 | Serious | ||
| Penalty | Z: Issued | 12/18/2017 | $12,549.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: Main Processing Area - The Cryovac 2045D machine's point of operation was not adequately guarded to prevent an employee from having his hand in the danger zone during the operating cycle.
Translate