Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1276875.015
Citation: 01001
Citation Type: Serious
Abatement Date: 01/03/2018 2
Initial Penalty: $9,234.00
Current Penalty: $9,234.00
Issuance Date: 12/06/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0317500
Contest Date:
Final Order: 01/03/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 12/06/2017 | $9,234.00 | 01/03/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) Facility, 1150 Second Avenue, New Kensington, PA: On or about November 14, 2017 authorized employees who perform servicing and maintenance on equipment had not been trained in the recognition of applicable energy sources or the methods and means necessary for energy isolation. A maintenance employee was injured when a pneumatic lift table being serviced lost air and fell. The employee had not been instructed on the methods or means necessary for energy isolation and had not isolated the air or used blocks to control potential release of energy.
Translate