Violation Detail
Standard Cited: 19100027 A Scaffolds and rope descent systems.
Inspection Nr: 1276566.015
Citation: 01001
Citation Type: Serious
Abatement Date: 03/14/2018 2
Initial Penalty: $5,607.00
Current Penalty: $3,364.20
Issuance Date: 03/06/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 03/19/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/19/2018 | $3,364.20 | 03/14/2018 | Serious | |
| Penalty | Z: Issued | 03/06/2018 | $5,607.00 | 03/14/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.27(a): Scaffolds used in general industry did not meet the requirements in 29 CFR part 1926, subpart L (Scaffolds), in that front-end loaders and similar pieces of equipment was used to support scaffold platforms which was not specifically designed by the manufacturer for such use. On or about October 26, 2017, an employee was working from a wooden pallet, which was elevated by a forklift, in order to reach a dust collector to remove build-up debris from its duct work. This exposed employee(s) to struck-by and/or fall hazards.