Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1274974.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 12/19/2017 2
Initial Penalty: $12,675.00
Current Penalty: $7,605.00
Issuance Date: 11/27/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 12/20/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/20/2017 | $7,605.00 | 12/19/2017 | Serious | |
| Penalty | Z: Issued | 11/27/2017 | $12,675.00 | 12/19/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Merge Conveyor - On or about October 31, 2017 horizontal pulley not guarded.
Translate