Violation Detail
Standard Cited: 19100213 L02 Woodworking machinery requirements.
Inspection Nr: 1272218.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/04/2017 2
Initial Penalty: $6,157.00
Current Penalty: $4,617.75
Issuance Date: 11/14/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 12/15/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/15/2017 | $4,617.75 | 12/04/2017 | Serious | |
| Penalty | Z: Issued | 11/14/2017 | $6,157.00 | 12/04/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.213(l)(2): Boring bits where not provided with guards that would enclose all portions of the bit and chuck above the material being worked. a) Frameless Building - Employees using the Ritter 4 bit drill were exposed to unguarded portions of the bits, on or about October 18th, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.