Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1271176.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $11,408.00
Current Penalty: $0.00
Issuance Date: 12/11/2017
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): A
Gravity: 10
Report ID: 0522300
Contest Date: 12/15/2017
Final Order: 05/02/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/02/2018 | $0.00 | Serious | ||
| Penalty | C: Contested | 02/09/2018 | $11,408.00 | Serious | ||
| Penalty | Z: Issued | 12/11/2017 | $11,408.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage: On or about October 7, 2017, the employer failed to ensure that the procedures were utilized by setup personnel prior to making adjustments to the dies in place on the press.