Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1270543.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/29/2017 2
Initial Penalty: $12,675.00
Current Penalty: $7,605.00
Issuance Date: 11/01/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): A
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 11/21/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/21/2017 | $7,605.00 | 12/29/2017 | Serious | |
| Penalty | Z: Issued | 11/01/2017 | $12,675.00 | 11/28/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Reynolds & Reynolds Co. on or about October 6, 2017 at the address of 412 Schunck Rd. Celina, OH: The employer did not to ensure that employees who are tasked with cleaning activities on the Rotary Printing Press #462 were adequately trained on the purpose and elements of the safe application and use relating to the isolation and control of hazardous energy sources. Employees tasked with cleaning activities at or near the point of rotation (nip-points) on the aforementioned machine, were not specifically trained to lockout the machine to protect against amputation injuries.