Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1263472.015
Citation: 01002
Citation Type: Serious
Abatement Date: 12/28/2017 2
Initial Penalty: $12,549.00
Current Penalty: $7,500.00
Issuance Date: 11/08/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0134000
Contest Date:
Final Order: 11/30/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/30/2017 | $7,500.00 | 12/28/2017 | Serious | |
| Penalty | Z: Issued | 11/08/2017 | $12,549.00 | 12/28/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Location - Production: On or about 9/8/17, the employer did not adequately train an employee to deenergize roll processing equipment prior to performing maintenance on it.