Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1262881.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 11/01/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/03/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 11/09/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/09/2017 | $0.00 | 11/01/2017 | Serious | |
| Penalty | Z: Issued | 10/03/2017 | $0.00 | 11/01/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt. The belt and pulley to the Bartelt machine in the powder filling room was not guarded, exposing employees to ingoing nip point hazards.