Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1259669.015
Citation: 01001
Citation Type: Serious
Abatement Date: 10/31/2017 2
Initial Penalty: $5,926.00
Current Penalty: $3,555.60
Issuance Date: 10/16/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 11/06/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/06/2017 | $3,555.60 | 10/31/2017 | Serious | |
| Penalty | Z: Issued | 10/16/2017 | $5,926.00 | 10/31/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a. Gemata Roller Coater 2200 - On or about August 29, 2017 the specific energy control procedures posted on the Roller Coater 2200 did not clearly identify steps for isolating energy sources.
Translate