Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1256387.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 12/15/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/01/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 11/29/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/29/2017 | $0.00 | 12/15/2017 | Serious | |
| Penalty | Z: Issued | 11/01/2017 | $0.00 | 11/29/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: (a) Parallel Products of Colorado, LLC. at 123 9th Ave., Greeley, CO 80631: On and before August 18, 2017, the employer did not ensure that a periodic inspection of the energy control procedures was conducted at least annually to ensure that the procedures and the requirements of this standard were being followed. The employees performed greasing and maintenance on machines such as, but not limited to, the baler, the auger, and the can crusher, and the employer did not conduct inspections to ensure that energy control procedures were in place. This condition resulted exposure to amputation hazards. Abatement note: 29 CFR 1910.147(c)(6)(ii) provides that the employer shall certify that periodic inspections were performed.