Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1255147.015
Citation: 01003
Citation Type: Other
Abatement Date: 01/16/2018 2
Initial Penalty: $3,232.00
Current Penalty: $1,939.20
Issuance Date: 12/20/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity:
Report ID: 0419400
Contest Date:
Final Order: 01/17/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/17/2018 | $1,939.20 | 01/16/2018 | Other | |
| Penalty | Z: Issued | 12/20/2017 | $3,232.00 | 01/16/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) Plant site - On or about August 14, 2017 the employer had not certified that a periodic inspection of energy control procedures had been performed, such as but not limited to, the procedure to control the unexpected startup of drag chain conveyor while employee(s) removed asphalt build-up from doors.