Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1253949.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/29/2017 2
Initial Penalty: $12,675.00
Current Penalty: $7,436.00
Issuance Date: 11/09/2017
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): A
Gravity: 10
Report ID: 0524700
Contest Date: 12/05/2017
Final Order: 08/06/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 08/06/2018 | $7,436.00 | 11/29/2017 | Serious | |
| Penalty | C: Contested | 12/06/2017 | $12,675.00 | 11/29/2017 | Serious | |
| Penalty | Z: Issued | 11/09/2017 | $12,675.00 | 11/29/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a.) On August 1, 2017, the employer did not ensure that all residual energy was restrained while performing maintenance on the side arm of the #2401 McNeilus automated side loader refuse truck (Model 42). An employee was performing maintenance on the raised hydraulic side arm, when it unexpectedly released pressure and came down on the employees arm, resulting in crushing injuries.