Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1247539.015
Citation: 01001
Citation Type: Serious
Abatement Date: 10/12/2017 2
Initial Penalty: $5,070.00
Current Penalty: $2,535.00
Issuance Date: 09/28/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 11/21/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/21/2017 | $2,535.00 | 10/12/2017 | Serious | |
| Penalty | Z: Issued | 09/28/2017 | $5,070.00 | 10/12/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees: On or about July 7, 2017 two employees working in an excavation 7 feet in depth were not provided with a ladder or other means of safe egress from the excavation within 25 lateral feet of their work location.