Violation Detail
Standard Cited: 19260451 B01 General requirements.
Inspection Nr: 1247040.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 08/11/2017 2
Initial Penalty: $1,630.00
Current Penalty: $978.00
Issuance Date: 08/07/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0625400
Contest Date:
Final Order: 11/09/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/09/2017 | $978.00 | 08/11/2017 | Serious | |
| Penalty | Z: Issued | 08/07/2017 | $1,630.00 | 08/11/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). On or about 14 July 2017, and at times prior thereto, three workers were on a scaffold performing masonry work at a level that was not fully planked, exposing them to a fall hazard of approximately 14 to 15 feet to the concrete below.