Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1243642.015
Citation: 01005A
Citation Type: Serious
Abatement Date: 10/17/2017 2
Initial Penalty: $5,070.00
Current Penalty: $4,000.00
Issuance Date: 09/27/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0418600
Contest Date:
Final Order: 10/17/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/17/2017 | $4,000.00 | 10/17/2017 | Serious | |
Penalty | Z: Issued | 09/27/2017 | $5,070.00 | 10/17/2017 | Serious |
Text For Citation: 01 Item/Group: 005A Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Drying oven exit - exit of oven: On or about June 26, 2017 the employer exposed employees to caught-by hazards in that a 2.5 inches diameter solid shaft projected 2.5 inch and was unguarded.