Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1241496.015
Citation: 01001
Citation Type: Serious
Abatement Date: 09/08/2017 2
Initial Penalty: $3,622.00
Current Penalty: $3,622.00
Issuance Date: 08/21/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0728900
Contest Date:
Final Order: 09/15/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 08/21/2017 | $3,622.00 | 09/08/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: The employer is failing to protect employees from amputation, electrical and caught between hazards associated with maintaining and cleaning equipment without having developed written specific procedures outlining the safe de-energizing and securing of stored energy. This was most occurrence of this was evident during the inspection of the facility located at 126 West Grant St., West Point, NE, where the employer has employees clean the turkey jerky ribbon blender under lockout without having a written specific procedure to validate the steps taken were effective.
Translate