Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1239173.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/22/2017 2
Initial Penalty: $8,873.00
Current Penalty: $5,323.00
Issuance Date: 09/27/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0830600
Contest Date:
Final Order: 11/01/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/01/2017 | $5,323.00 | 11/22/2017 | Serious | |
| Penalty | Z: Issued | 09/27/2017 | $8,873.00 | 10/03/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about May 30, 2017 and at times prior, the employer did not establish and utilize a procedure for safely servicing pressurized equipment to ensure that employees were protected from struck-by and burn injuries, to include but not limited to the Collectramatic fryer cooker.