Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1239066.015
Citation: 01001
Citation Type: Serious
Abatement Date: 08/10/2017 2
Initial Penalty: $12,675.00
Current Penalty: $0.00
Issuance Date: 07/18/2017
Nr Instances: 1
Nr Exposed: 649
Related Event Code (REC): A
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 08/10/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/10/2017 | $0.00 | 08/10/2017 | Serious | |
| Penalty | Z: Issued | 07/18/2017 | $12,675.00 | 08/10/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Arcelormittal Tubular Products Shelby LLC on or about June 5, 2017, at the address of 132 West Main St. Shelby, OH (Plant #2): The employer did not ensure that machine/equipment specific energy control procedures were developed and utilized to control potentially hazardous energy sources while an employee performed repair work on an 8 inch pneumatic cylinder. The employee, disassembling the cylinder in a condition in which stored pneumatic energy was not isolated or blocked, was exposed to struck-by hazards.
Translate