Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1237708.015
Citation: 01002
Citation Type: Other
Abatement Date: 12/04/2017 2
Initial Penalty: $10,864.00
Current Penalty: $7,605.00
Issuance Date: 10/27/2017
Nr Instances: 6
Nr Exposed: 2
Related Event Code (REC): R
Gravity:
Report ID: 0625500
Contest Date:
Final Order: 11/13/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/13/2017 | $7,605.00 | 12/04/2017 | Other | |
| Penalty | Z: Issued | 10/27/2017 | $10,864.00 | 11/06/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): SkyScreamer, inside the star: On or about May 28, 2017, and at times prior thereto, employees were exposed to a caught in hazard due to unguarded wire ropes, which were used to raise and lower the gondola of the ride.
Translate