Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1235805.015
Citation: 01004C
Citation Type: Serious
Abatement Date: 09/07/2017 2
Initial Penalty: $2,716.00
Current Penalty: $0.00
Issuance Date: 08/11/2017
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 08/30/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/30/2017 | $0.00 | 09/07/2017 | Serious | |
| Penalty | Z: Issued | 08/11/2017 | $2,716.00 | 09/07/2017 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end, and projected more than one half the diameter of the shaft: (a) Trimmer, Operator Side: On May 24, 2017 and times prior, employees were exposed to a horizontal rotating shaft end that was 1 and 1/2 inch in diameter and projected 5 inches from the trimmer. The shaft end was 24 inches above floor level and had two pieces metal that projected 3/4 of an inch perpendicular to the shaft. (b) Trimmer, Non-Operator Side: On May 24, 2017 and times prior, employees were exposed to a horizontal rotating shaft end that was 1 and 1/2 inch in diameter and projected 4 and 1/2 inches from the trimmer. The shaft end was 27 inches above floor level and had two pieces metal that projected 3/4 of an inch perpendicular to the shaft.
Translate