Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1233867.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 08/10/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/23/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 07/10/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/10/2017 | $0.00 | 08/10/2017 | Serious | |
| Penalty | Z: Issued | 06/23/2017 | $0.00 | 07/20/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) On or about 05/17/2017 - Production area, employees performing maintenance activities such as cleaning and changing belts with electrical, pneumatic, and hydraulic sources of energy were unaware of the hazards.