Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1231906.015
Citation: 01003
Citation Type: Serious
Abatement Date: 08/03/2017 2
Initial Penalty: $7,985.00
Current Penalty: $0.00
Issuance Date: 06/16/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 07/05/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/05/2017 | $0.00 | 08/03/2017 | Serious | |
| Penalty | Z: Issued | 06/16/2017 | $7,985.00 | 08/03/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (a) On or about 5/9/2017 the employer did not properly train employees on the methods of energy isolation and control for the Spoil tank door in that employees were not aware that there was a safety pin that locks in place to prevent movement of the Spoil tank door during cleaning.