Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1231210.015
Citation: 01001D
Citation Type: Serious
Abatement Date: 08/02/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/07/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 07/27/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/27/2017 | $0.00 | 08/02/2017 | Serious | |
| Penalty | Z: Issued | 07/07/2017 | $0.00 | 08/02/2017 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Three Rivers Calf Ranch: On or about April 18, 2017 and at times prior, an employee was burned while servicing a propane vaporizer. Abatement certification and documentation is required for this item.
Translate