Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1229770.015
Citation: 01001
Citation Type: Other
Abatement Date: 3
Initial Penalty: $12,675.00
Current Penalty: $6,337.50
Issuance Date: 09/22/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity:
Report ID: 0522000
Contest Date:
Final Order: 10/11/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/11/2017 | $6,337.50 | Other | ||
| Penalty | Z: Issued | 09/22/2017 | $12,675.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a) On April 28, 2017 guarding was not in place to prevent employees exposure to rotating shaft while feeding rope onto Paper Machine #24.
Translate