Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1228838.015
Citation: 01001B
Citation Type: Other
Abatement Date: 01/29/2018 2
Initial Penalty: $12,675.00
Current Penalty: $0.00
Issuance Date: 09/12/2017
Nr Instances: 1
Nr Exposed: 35
Related Event Code (REC): R
Gravity:
Report ID: 0213100
Contest Date: 10/06/2017
Final Order: 12/29/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 12/29/2017 | $0.00 | 01/29/2018 | Other | |
| Penalty | C: Contested | 10/10/2017 | $12,675.00 | 09/22/2017 | Serious | |
| Penalty | Z: Issued | 09/12/2017 | $12,675.00 | 09/22/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Symbotic structure - On or about April 15, 2017, the employer did not have lockout/ tagout devices affixed to the MVC (multilevel vehicle conveyor). An employee sustained serious hand injuries when his hand was caught in between the structure and the MVC while working on a bot charging station.
Translate