Violation Detail
Standard Cited: 19100217 C01 I Mechanical power presses.
Inspection Nr: 1227152.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 10/25/2017 2
Initial Penalty: $3,803.00
Current Penalty: $0.00
Issuance Date: 09/28/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 10/24/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/24/2017 | $0.00 | 10/25/2017 | Serious | |
| Penalty | Z: Issued | 09/28/2017 | $3,803.00 | 10/25/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.217(c)(1)(i): It shall be the responsibility of the employer to provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10. (1) Employees operating the Minster Partial Revolution Mechanical Power Press #1 was exposed to the unguarded point of operation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Translate