Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1227121.015
Citation: 01009
Citation Type: Serious
Abatement Date: 11/01/2017 2
Initial Penalty: $5,070.00
Current Penalty: $500.00
Issuance Date: 10/05/2017
Nr Instances: 2
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0627510
Contest Date: 12/04/2017
Final Order: 12/27/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 04/23/2019 | $5,070.00 | 11/01/2017 | Serious | |
Penalty | J: ALJ Decision | 12/27/2018 | $500.00 | 11/01/2017 | Serious | |
Penalty | Z: Issued | 10/05/2017 | $5,070.00 | 11/01/2017 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: In the spray area on the west side of the main shop, employees engaged in painting activities with unguarded fans were exposed to struck-by and caught-in hazards.