Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1224646.015
Citation: 01002
Citation Type: Other
Abatement Date: 06/26/2017 2
Initial Penalty: $11,408.00
Current Penalty: $11,408.00
Issuance Date: 05/23/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity:
Report ID: 0522500
Contest Date:
Final Order: 06/20/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/20/2017 | $11,408.00 | 06/26/2017 | Other | |
| Penalty | Z: Issued | 05/23/2017 | $11,408.00 | 06/26/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lock-out or tag-out procedures) shall cover the following elements and actions and shall be done in the following sequence as required by 29 CFR 1910.147(d)(1)-(6): a) On or about April 4, 2017, a maintenance employee suffered the amputation of the tip of their middle finger when it became caught between a belt and pulley while performing a monthly fuel oil test on the Large Boiler #2. The employer failed to implement energy control application steps in order to safely perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LO/TO device application [(d)(4)], dissipation of residual energy [(d)(5)(i), and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.