Violation Detail
Standard Cited: 19100243 B02 Guarding of portable powered tools.
Inspection Nr: 1223846.015
Citation: 02001
Citation Type: Other
Abatement Date: 07/21/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/26/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity:
Report ID: 0317700
Contest Date:
Final Order: 07/11/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/11/2017 | $0.00 | 07/21/2017 | Other | |
| Penalty | Z: Issued | 06/26/2017 | $0.00 | 07/21/2017 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected. a) Boric acid feed system, Chemical feed platform, Production, 157 Passan Drive, Wilkes-Barre, PA - The Husky 3/8" ID, 300 psi hose carrying compressed air at 80 psi used to operate a Salina Vortex Corporation Orifice Slide Gate Model FA06 (Serial No. 55814-002) was attached by a Type-F worm drive hose clamp not designed for use with compressed air exposing employees to struck-by hazards from clamps or the whipping action of the hose, on or about March 23, 2017. b) Boric acid feed system, Chemical feed platform, Production, 157 Passan Drive, Wilkes-Barre, PA - The Husky 3/8" ID, 300 psi hose carrying compressed air at 80 psi used to operate a Vibco Pneumatic Piston Vibrator Model 55-2 was attached by a Type-F worm drive hose clamp not designed for use with compressed air exposing employees to struck-by hazards from clamps or the whipping action of the hose, on or about March 23, 2017. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Translate