Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1222136.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,864.00
Current Penalty: $8,691.20
Issuance Date: 09/06/2017
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 10/05/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/05/2017 | $8,691.20 | Serious | ||
| Penalty | Z: Issued | 09/06/2017 | $10,864.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. At the establishments' press area, employees operating the Gammerler Compensating Stacker, model KL 6000 were exposed to an inner pulley while removing jammed paper, on or about, 03/21/2017.