Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1221284.015
Citation: 01002
Citation Type: Serious
Abatement Date: 02/26/2018 2
Initial Penalty: $12,675.00
Current Penalty: $9,000.00
Issuance Date: 05/11/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0213100
Contest Date: 06/05/2017
Final Order: 02/16/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 02/16/2018 | $9,000.00 | 02/26/2018 | Serious | |
| Penalty | C: Contested | 06/08/2017 | $12,675.00 | 05/31/2017 | Serious | |
| Penalty | Z: Issued | 05/11/2017 | $12,675.00 | 05/31/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) On the first floor of the operating plant - On March 30, 2017, the baler had a missing guard that exposed a moving part, thereby creating a hazard..
Translate