Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1220436.015
Citation: 01002
Citation Type: Serious
Abatement Date: 08/25/2017 2
Initial Penalty: $12,675.00
Current Penalty: $8,000.00
Issuance Date: 07/11/2017
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): R
Gravity: 10
Report ID: 0418200
Contest Date: 08/03/2017
Final Order: 05/30/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/30/2018 | $8,000.00 | 08/25/2017 | Serious | |
| Penalty | C: Contested | 08/08/2017 | $12,675.00 | 08/25/2017 | Serious | |
| Penalty | Z: Issued | 07/11/2017 | $12,675.00 | 08/25/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Production Area; On or about March 27, 2017, and at times prior, the employer exposed employees to amputation hazards in that the employer failed to annually review the energy control procedure for Bailer #5 (Dens-A-Can International Model #DAC1200W0CONV, Serial #B244SPI0712) to ensure that employees were correctly following the procedures to clear a jam.