Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100107 B05 I Spray finishing using flammable and combustible materials.

Inspection Nr: 1219419.015

Citation: 01002A

Citation Type: Other

Abatement Status: Abatement Completed

Initial Penalty: $8,873.00

Current Penalty: $0.00

Issuance Date: 07/28/2017

Nr Instances: 1

Nr Exposed: 10

Abatement Date: 03/19/2018

Gravity:

Report ID: 0523400

Contest Date: 08/22/2017

Final Order: 01/18/2018

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 01/18/2018 $0.00 03/19/2018 Other  
Penalty C: Contested 08/30/2017 $8,873.00 08/09/2017 Serious  
Penalty Z: Issued 07/28/2017 $8,873.00 08/09/2017 Serious  

Text For Citation: 01 Item/Group: 002A Hazard:

29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained. (a) There was no visible gauge or other device installed on the paint booth to indicate that airflow in the paint booth was being maintained in order to prevent accumulation of flammable paint vapor.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.