Violation Detail
Standard Cited: 19100254 B04 IV Arc welding and cutting.
Inspection Nr: 1216213.015
Citation: 01005
Citation Type: Serious
Abatement Date: 04/21/2017 3
Initial Penalty: $5,432.00
Current Penalty: $2,716.00
Issuance Date: 04/11/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 1
Report ID: 0729700
Contest Date:
Final Order: 04/26/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/26/2017 | $2,716.00 | 04/21/2017 | Serious | |
| Penalty | Z: Issued | 04/11/2017 | $5,432.00 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.254(b)(4)(iv): Terminals for welding leads were not protected from accidental contact by personnel or metal objects: In department #15, an employee engaged in welding activities with the use of a Miller Deltaweld 452 Welder was exposed to electrical shock hazards in that a guard/terminal cover was not in place to prevent contact with the exposed terminals.
Translate