Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1215292.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,054.00
Current Penalty: $6,790.50
Issuance Date: 03/14/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 03/23/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/23/2017 | $6,790.50 | Serious | ||
| Penalty | Z: Issued | 03/14/2017 | $9,054.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): (a) Revert Processing Center: On or about March 1, 2017 the drive belt powering the shaker table for the crusher did not have a guard covering it which exposed employees to a pinch point hazard.