Violation Detail
Standard Cited: 19260652 B02 Requirements for protective systems.
Inspection Nr: 1211661.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 04/11/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/21/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 05/16/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/16/2017 | $0.00 | 04/11/2017 | Serious | |
Penalty | Z: Issued | 03/21/2017 | $0.00 | 04/11/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.652(b)(2): Maximum allowable slopes, and allowable configurations for sloping and benching systems, was not determined in accordance with the conditions and requirements set forth in Appendices A and B to this subpart. On or about February 16, 2017 and times prior thereto, in a greater than 5 foot excavation, where employees were performing stick welding on a 10 inch steel gas pipe, the soil and rock deposits had not been adequately classified by a competent person as Stable Rock, Type A, Type B, or Type C.