Violation Detail
Standard Cited: 19100213 E01 Woodworking machinery requirements.
Inspection Nr: 1211505.015
Citation: 01001
Citation Type: Serious
Abatement Date: 1
Initial Penalty: $3,663.00
Current Penalty: $2,197.80
Issuance Date: 04/04/2017
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0418200
Contest Date:
Final Order: 06/28/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/28/2017 | $2,197.80 | Serious | ||
| Penalty | Z: Issued | 04/04/2017 | $3,663.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.213(e)(1): Each circular saw shall be guarded by a hood or shield of metal above the saw. This hood or shield shall be so designed as to guard against danger from flying splinters or broken saw teeth. a) Block 1, Saw Mill: On or about February 10, 2017 and at times prior, the employer exposed employees to struck-by hazards when working in close proximity to an unguarded circular saw. B) Block 2, Saw Mill: On or about February 10, 2017 and at times prior, the employer exposed employees to struck-by hazards when working in close proximity to an unguarded circular saw.