Violation Detail
Standard Cited: 19100140 D02 II
Inspection Nr: 1207150.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/01/2017 2
Initial Penalty: $9,760.00
Current Penalty: $4,880.00
Issuance Date: 05/05/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 05/17/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/17/2017 | $4,880.00 | 06/01/2017 | Serious | |
| Penalty | Z: Issued | 05/05/2017 | $9,760.00 | 06/01/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.140(d)(2)(ii): (ii) Personal fall arrest systems were not rigged in such a manner that the employee cannot free fall more than 6 feet (1.8 m) or contact a lower level. A free fall may be more than 6 feet (1.8 m) provided the employer can demonstrate the manufacturer designed the system to allow a free fall of more than 6 feet and tested the system to ensure a maximum arresting force of 1,800 pounds (8 kN) is not exceeded. A) At the Terminal Access Road overpass for the Ben Griffin Parkway in Fort Myers where an employee that was replacing metal sign panels was ejected from a JLG aerial lift. The personal fall arrest system used by the employee failed to arrest the fall. Employee fell approximately 18 feet, as observed on or about 01/21/2017.