Violation Detail
Standard Cited: 19100132 D01 General requirements.
Inspection Nr: 1196975.015
Citation: 01001
Citation Type: Serious
Abatement Date: 07/24/2017 2
Initial Penalty: $6,519.00
Current Penalty: $4,200.00
Issuance Date: 05/08/2017
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC): A
Gravity: 5
Report ID: 0728900
Contest Date:
Final Order: 05/31/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/31/2017 | $4,200.00 | 07/24/2017 | Serious | |
| Penalty | Z: Issued | 05/08/2017 | $6,519.00 | 06/23/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): Neapco Components - Buildings 1-4 - 501 W. Sargent Street - Beatrice, Nebraska - Employer is failing to conduct and document a hazard assessment to ensure that Mosaic employee(s) use appropriate personal protective equipment at the facility. A documented hazard assessment was not available upon agency request. Employees exposed to corrosive liquids including, but not limited to toilet bowl cleaner, chlorine bleach, and lime scale/rust remover did not wear goggles or face shields. This violation was last observed on or about December 12, 2016.